    <description>&lt;P&gt;Hello, &lt;SPAN&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;SPAN class="UserName lia-user-name lia-user-rank-11-Garnet lia-component-message-view-widget-author-username"&gt;&lt;A id="link_18" class="lia-link-navigation lia-page-link lia-user-name-link" href="https://community.ptc.com/t5/user/viewprofilepage/user-id/608591" target="_self" aria-label="View Profile of DurgaK"&gt;&lt;SPAN class=""&gt;DurgaK&lt;/SPAN&gt;&lt;/A&gt;&lt;/SPAN&gt;, I could not solve the problem&lt;/P&gt;</description>
    <pubDate>Thu, 01 Jun 2023 05:57:37 GMT</pubDate>
    <dc:creator>VladiSlav</dc:creator>
    <dc:date>2023-06-01T05:57:37Z</dc:date>
    <item>
      <title>Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/822982#M1864</link>
      <description>&lt;P&gt;We are trying&amp;nbsp;to configure a custom Windchill worker to generate Creo View Representations in PDF format&lt;BR /&gt;of AutoCAD dwg, dxf files&amp;nbsp;referring to this article:&amp;nbsp;&lt;A href="https://www.ptc.com/en/support/article/CS40919" target="_blank" rel="noopener"&gt;https://www.ptc.com/en/support/article/CS40919&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;We are currently experiencing an error:&amp;nbsp;&lt;SPAN&gt;"..cannot produce output file xxx.out ".&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;How to solve this problem?&lt;/P&gt;</description>
      <pubDate>Fri, 15 Mar 2024 14:07:38 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/822982#M1864</guid>
      <dc:creator>VladiSlav</dc:creator>
      <dc:date>2024-03-15T14:07:38Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/823143#M1865</link>
      <description />
      <pubDate>Tue, 13 Sep 2022 05:04:39 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/823143#M1865</guid>
      <dc:creator>VladiSlav</dc:creator>
      <dc:date>2022-09-13T05:04:39Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/875819#M1866</link>
      <description>&lt;P&gt;Hi Valdi,&lt;/P&gt;&lt;P&gt;Were you able to configure the AutoCAD worker&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Wed, 17 May 2023 07:12:13 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/875819#M1866</guid>
      <dc:creator>DKWc</dc:creator>
      <dc:date>2023-05-17T07:12:13Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/878711#M1867</link>
      <description>&lt;P&gt;Hello, &lt;SPAN&gt;&amp;nbsp;&lt;/SPAN&gt;&lt;SPAN class="UserName lia-user-name lia-user-rank-11-Garnet lia-component-message-view-widget-author-username"&gt;&lt;A id="link_18" class="lia-link-navigation lia-page-link lia-user-name-link" href="https://community.ptc.com/t5/user/viewprofilepage/user-id/608591" target="_self" aria-label="View Profile of DurgaK"&gt;&lt;SPAN class=""&gt;DurgaK&lt;/SPAN&gt;&lt;/A&gt;&lt;/SPAN&gt;, I could not solve the problem&lt;/P&gt;</description>
      <pubDate>Thu, 01 Jun 2023 05:57:37 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/878711#M1867</guid>
      <dc:creator>VladiSlav</dc:creator>
      <dc:date>2023-06-01T05:57:37Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/878727#M1868</link>
      <description>&lt;P&gt;&lt;a href="https://www.ptcusercommunity.com/t5/user/viewprofilepage/user-id/306401"&gt;@VladiSlav&lt;/a&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Have you tried this article?&lt;/P&gt;
&lt;P&gt;&lt;A href="https://www.ptc.com/en/support/article/CS347429" target="_blank"&gt;https://www.ptc.com/en/support/article/CS347429&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;PetrH&lt;/P&gt;</description>
      <pubDate>Thu, 01 Jun 2023 06:50:06 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/878727#M1868</guid>
      <dc:creator>HelesicPetr</dc:creator>
      <dc:date>2023-06-01T06:50:06Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/879515#M1869</link>
      <description>&lt;P&gt;Hi Validi,&lt;/P&gt;&lt;P&gt;Followed the article&amp;nbsp;&lt;A href="https://www.ptc.com/en/support/article/CS40919" target="_blank" rel="noopener nofollow"&gt;https://www.ptc.com/en/support/article/CS40919&lt;/A&gt;. Able to configure worker and turn on.&lt;/P&gt;&lt;P&gt;The good part is it's trying to publish as well, however, the hurdle is accorconsole.exe is not creating any pdf.&lt;/P&gt;&lt;P&gt;If I place a dummy .pdf file in ftp folder created the representation is getting generated.&lt;/P&gt;&lt;P&gt;Tried to have a deep dive and found some bottleneck.&lt;/P&gt;&lt;P&gt;AutoCADWorker.bat triggers -&amp;gt; workerjava.bat which triggers -&amp;gt; customgenericeworker.java which triggers -&amp;gt; pdfconvertor.bat&amp;nbsp; which actually picks up the .dwg from FTP folder and creates .pdf in the same folder. Then windchill worker picks up the pdf to create representation. ( The said files are provided in CS40919.)&lt;/P&gt;&lt;P&gt;Tried manually publishing pdf using accorconsole, creating bat script it's working fine.&lt;/P&gt;&lt;P&gt;The script from pdfconvertor.bat file&lt;/P&gt;&lt;P&gt;%CONVERTER% /i %1 /s %2 /l &amp;gt; AcCoreConsole.log 2&amp;gt;&amp;amp;1.&lt;/P&gt;&lt;P&gt;In this script where do we find %1 and %2 value defined? Any idea.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 06 Jun 2023 07:17:02 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/879515#M1869</guid>
      <dc:creator>DKWc</dc:creator>
      <dc:date>2023-06-06T07:17:02Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/879518#M1870</link>
      <description>&lt;P&gt;Hi&amp;nbsp;&lt;a href="https://www.ptcusercommunity.com/t5/user/viewprofilepage/user-id/608591"&gt;@DKWc&lt;/a&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Edit the bat file and add a line&amp;nbsp;&lt;/P&gt;
&lt;P&gt;echo&amp;nbsp;&lt;SPAN&gt;/i %1 /s %2 &amp;gt; c:\logpdfconvertor.log&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;this will show you the values if the script is run.&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;you will find it in c:\logpdfconvertor.log file. Sure you can point to an another location.&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;SPAN&gt;PetrH&lt;/SPAN&gt;&lt;/P&gt;</description>
      <pubDate>Tue, 06 Jun 2023 07:23:37 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/879518#M1870</guid>
      <dc:creator>HelesicPetr</dc:creator>
      <dc:date>2023-06-06T07:23:37Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/879519#M1871</link>
      <description>&lt;P&gt;Hi&amp;nbsp;&lt;a href="https://www.ptcusercommunity.com/t5/user/viewprofilepage/user-id/241117"&gt;@HelesicPetr&lt;/a&gt;&amp;nbsp;,&lt;/P&gt;&lt;P&gt;Thanks for the reply.&lt;BR /&gt;From where and we can reset/change the values?&lt;/P&gt;</description>
      <pubDate>Tue, 06 Jun 2023 07:32:54 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/879519#M1871</guid>
      <dc:creator>DKWc</dc:creator>
      <dc:date>2023-06-06T07:32:54Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/879520#M1872</link>
      <description>&lt;P&gt;Hi&amp;nbsp;&lt;a href="https://www.ptcusercommunity.com/t5/user/viewprofilepage/user-id/608591"&gt;@DKWc&lt;/a&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Who knows. You need to find it.&amp;nbsp;&lt;/P&gt;
&lt;P&gt;If you know values, you can search for it.&lt;/P&gt;
&lt;P&gt;For example try to search a string values in all files and so on. If you are lucky you will find them.&lt;/P&gt;
&lt;P&gt;I advice you how to get the value, now it is up to you to find the location where are defined.&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;PS: you find that the bat file is run from&amp;nbsp;&lt;SPAN&gt;customgenericeworker.java&amp;nbsp;so in this class there are the variables I guess.&amp;nbsp;&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;PetrH&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 06 Jun 2023 07:39:20 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/879520#M1872</guid>
      <dc:creator>HelesicPetr</dc:creator>
      <dc:date>2023-06-06T07:39:20Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/880748#M1873</link>
      <description>&lt;P&gt;Hi All,&lt;/P&gt;&lt;P&gt;Seems the efforts finally paying off. The pdf is getting generated in the tmp folder however it comes with the suffix "-model".&lt;/P&gt;&lt;P&gt;Eg 56GF-Model.pdf , due to this the server is not able to pick the pdf file and generate representation.&lt;/P&gt;&lt;P&gt;If manually delete the suffix from pdf generated representation is getting generated.&lt;/P&gt;&lt;P&gt;The scr been used is attached.&lt;/P&gt;&lt;P&gt;Tried multiple ways still, suffix is getting generated.&lt;/P&gt;&lt;P&gt;Any suggestions on how to get rid of the suffix?&lt;/P&gt;&lt;P&gt;thanks in advance.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Regards,&lt;/P&gt;&lt;P&gt;Durga&lt;/P&gt;</description>
      <pubDate>Tue, 13 Jun 2023 09:42:35 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/880748#M1873</guid>
      <dc:creator>DKWc</dc:creator>
      <dc:date>2023-06-13T09:42:35Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/880952#M1874</link>
      <description>&lt;P&gt;Hi&amp;nbsp;&lt;a href="https://www.ptcusercommunity.com/t5/user/viewprofilepage/user-id/608591"&gt;@DKWc&lt;/a&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Because I don't know how a configuration is set in the system and I guess you can not change the behavior I would use a&amp;nbsp;&lt;STRONG&gt;WVS&amp;nbsp;Afterloader&amp;nbsp;&lt;/STRONG&gt;action where you can change the name of the PDF document.&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;here is example how the WVS Afterloader works.&amp;nbsp;&lt;A href="https://www.ptc.com/en/support/article/CS349681" target="_blank" rel="noopener"&gt;CS349681&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Hope the idea can help&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;PetrH&lt;/P&gt;</description>
      <pubDate>Wed, 14 Jun 2023 06:09:44 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/880952#M1874</guid>
      <dc:creator>HelesicPetr</dc:creator>
      <dc:date>2023-06-14T06:09:44Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/880959#M1875</link>
      <description>&lt;P&gt;Hi,&lt;/P&gt;&lt;P&gt;Thanks for the reply.&lt;/P&gt;&lt;P&gt;The proposed case is to rename the representations which are generated.&lt;/P&gt;&lt;P&gt;The actual scenario is the representation is not getting generated because the published pdf with the use of accoreconsole has a suffix that stops Windchill to pick up the published pdf from the temp folder. (EPM doc name and published pdf name differs due to suffix, which doesn't generate representation.)&lt;/P&gt;&lt;P&gt;If the suffix gets eliminated representation is generated.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Regards,&lt;/P&gt;&lt;P&gt;Durga&lt;/P&gt;</description>
      <pubDate>Wed, 14 Jun 2023 06:45:18 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/880959#M1875</guid>
      <dc:creator>DKWc</dc:creator>
      <dc:date>2023-06-14T06:45:18Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/880969#M1876</link>
      <description>&lt;P&gt;Hi&amp;nbsp;&lt;a href="https://www.ptcusercommunity.com/t5/user/viewprofilepage/user-id/608591"&gt;@DKWc&lt;/a&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;My bad, I thought that the representation is created without pdf so my idea with WVS Afterloader can not work.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;There has to be some configuration where the suffix is defined... for example publish rules&amp;nbsp;&lt;A href="https://www.ptc.com/en/support/article/CS111916" target="_blank" rel="noopener"&gt;CS111916&lt;/A&gt;&amp;nbsp;where suffix or prefix is set for additional files.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;what PTC support tells you?&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;PetrH&lt;/P&gt;</description>
      <pubDate>Wed, 14 Jun 2023 07:16:31 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/880969#M1876</guid>
      <dc:creator>HelesicPetr</dc:creator>
      <dc:date>2023-06-14T07:16:31Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/880973#M1877</link>
      <description>&lt;P&gt;Hi&amp;nbsp;&lt;a href="https://www.ptcusercommunity.com/t5/user/viewprofilepage/user-id/608591"&gt;@DKWc&lt;/a&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;the case describes a script to add&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="HelesicPetr_0-1686727232430.png" style="width: 400px;"&gt;&lt;img src="https://www.ptcusercommunity.com/t5/image/serverpage/image-id/83543iA0681AB1739A8A91/image-size/medium?v=v2&amp;amp;px=400" role="button" title="HelesicPetr_0-1686727232430.png" alt="HelesicPetr_0-1686727232430.png" /&gt;&lt;/span&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Can you use this place for renaming the generated PDF? Or somewhere else?&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;PetrH&lt;/P&gt;</description>
      <pubDate>Wed, 14 Jun 2023 07:21:19 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/880973#M1877</guid>
      <dc:creator>HelesicPetr</dc:creator>
      <dc:date>2023-06-14T07:21:19Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/881144#M1878</link>
      <description>&lt;P&gt;You could try using ‘EXPORT’ in the scr instead of PLOT, export is like save as pdf rather than print a pdf, I used export for custom autocad workers and the pdf file name is the same as the drawing number + .pdf&lt;/P&gt;</description>
      <pubDate>Wed, 14 Jun 2023 18:01:50 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/881144#M1878</guid>
      <dc:creator>rhart</dc:creator>
      <dc:date>2023-06-14T18:01:50Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/881221#M1879</link>
      <description>&lt;P&gt;Hi,&lt;/P&gt;&lt;P&gt;Thanks for your reply.&lt;/P&gt;&lt;P&gt;If manually use export in AutoCAD UI it doesn't generate any prefixes or suffixes.&lt;/P&gt;&lt;P&gt;Any sample file scr you have for export.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Regards,&lt;/P&gt;&lt;P&gt;Durga&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Thu, 15 Jun 2023 05:33:13 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/881221#M1879</guid>
      <dc:creator>DKWc</dc:creator>
      <dc:date>2023-06-15T05:33:13Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/881225#M1880</link>
      <description>&lt;P&gt;Hi&amp;nbsp;&lt;a href="https://www.ptcusercommunity.com/t5/user/viewprofilepage/user-id/608591"&gt;@DKWc&lt;/a&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Use EXPORT instead of PLOT in your configuration&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="HelesicPetr_0-1686807548325.png" style="width: 400px;"&gt;&lt;img src="https://www.ptcusercommunity.com/t5/image/serverpage/image-id/83636i80824A52B2D8193E/image-size/medium?v=v2&amp;amp;px=400" role="button" title="HelesicPetr_0-1686807548325.png" alt="HelesicPetr_0-1686807548325.png" /&gt;&lt;/span&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Also I would play with the script that cares about pdf name&lt;/P&gt;
&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="HelesicPetr_0-1686808039139.png" style="width: 487px;"&gt;&lt;img src="https://www.ptcusercommunity.com/t5/image/serverpage/image-id/83637iE0F67569C701E39E/image-dimensions/487x95?v=v2" width="487" height="95" role="button" title="HelesicPetr_0-1686808039139.png" alt="HelesicPetr_0-1686808039139.png" /&gt;&lt;/span&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;PetrH&lt;/P&gt;</description>
      <pubDate>Thu, 15 Jun 2023 05:47:40 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/881225#M1880</guid>
      <dc:creator>HelesicPetr</dc:creator>
      <dc:date>2023-06-15T05:47:40Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/881287#M1881</link>
      <description>&lt;P&gt;&amp;nbsp;Sure, see attached.&lt;/P&gt;&lt;P&gt;In our case, we export only the paperspace views to PDF,&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Thu, 15 Jun 2023 09:45:31 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/881287#M1881</guid>
      <dc:creator>rhart</dc:creator>
      <dc:date>2023-06-15T09:45:31Z</dc:date>
    </item>
    <item>
      <title>Re: Custom Windchill worker for AutoCAD</title>
      <link>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/881306#M1882</link>
      <description>&lt;P&gt;This script exactly worked for me.&lt;/P&gt;&lt;P&gt;Thanks&amp;nbsp;&lt;STRONG&gt;HART&amp;nbsp;&lt;/STRONG&gt;you were popped in at exact right time.&lt;/P&gt;&lt;P&gt;This is working exactly as expected.&lt;/P&gt;&lt;P&gt;The publication is working fine.&lt;/P&gt;</description>
      <pubDate>Thu, 15 Jun 2023 10:15:07 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Windchill-Customization/Custom-Windchill-worker-for-AutoCAD/m-p/881306#M1882</guid>
      <dc:creator>DKWc</dc:creator>
      <dc:date>2023-06-15T10:15:07Z</dc:date>