<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: Intelligent fastner and personal order code in Customization</title>
    <link>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044308#M14610</link>
    <description>&lt;P&gt;Thank you so much for the clarification, i have to set the parameter every time that i open a fastner or it's possibile to change the parameter once ?&lt;/P&gt;</description>
    <pubDate>Fri, 21 Nov 2025 07:52:03 GMT</pubDate>
    <dc:creator>AC_9932786</dc:creator>
    <dc:date>2025-11-21T07:52:03Z</dc:date>
    <item>
      <title>Intelligent fastner and personal order code</title>
      <link>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044198#M14603</link>
      <description>&lt;P&gt;Good afternoon i'm using Creo parametric 11 with the intelligent fastner lite version.&lt;BR /&gt;I would like to know if it possibile to modify or add some screw starting from the template for have my personal codification.&lt;/P&gt;&lt;P&gt;Thank you for your time and help.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Thu, 20 Nov 2025 12:06:22 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044198#M14603</guid>
      <dc:creator>AC_9932786</dc:creator>
      <dc:date>2025-11-20T12:06:22Z</dc:date>
    </item>
    <item>
      <title>Re: Intelligent fastner and personal order code</title>
      <link>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044214#M14605</link>
      <description>&lt;P&gt;Hi,&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;customizing fasteners is not supported for the lite version.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;We only allow a set of parameter names:&lt;/P&gt;
&lt;P&gt;&lt;A href="https://support.ptc.com/help/creo/creo_pma/r11.0/usascii/#page/assembly/intelligent_fastener/Allowable_Model_Parameters.html#" target="_blank"&gt;Allowable Model Parameters&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;In addition the dat files cannot be modified. It is not possible to change the names of your fasteners.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;The full version of IFX is now included inside the Creo Design packages.&lt;/P&gt;
&lt;P&gt;&lt;A href="https://www.ptc.com/en/products/creo/packages" target="_blank"&gt;Creo Packages | PTC Products&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Thu, 20 Nov 2025 13:29:42 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044214#M14605</guid>
      <dc:creator>OliverGräbner</dc:creator>
      <dc:date>2025-11-20T13:29:42Z</dc:date>
    </item>
    <item>
      <title>Re: Intelligent fastner and personal order code</title>
      <link>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044308#M14610</link>
      <description>&lt;P&gt;Thank you so much for the clarification, i have to set the parameter every time that i open a fastner or it's possibile to change the parameter once ?&lt;/P&gt;</description>
      <pubDate>Fri, 21 Nov 2025 07:52:03 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044308#M14610</guid>
      <dc:creator>AC_9932786</dc:creator>
      <dc:date>2025-11-21T07:52:03Z</dc:date>
    </item>
    <item>
      <title>Re: Intelligent fastner and personal order code</title>
      <link>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044309#M14611</link>
      <description>&lt;P&gt;You can customize the existing parameter values by changing them inside the *.dat (&lt;A href="https://support.ptc.com/help/creo/creo_pma/r12/usascii/#page/assembly/intelligent_fastener/IFX_Fastener_Data_Files.html#" target="_blank"&gt;Fastener Data Files&lt;/A&gt;) file.&lt;/P&gt;
&lt;P&gt;If your fastener already exist it will not be modified. Existing fasteners will always be reused if possible.&lt;/P&gt;
&lt;P&gt;The modified parameters will only affect newly created fasteners.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;See also:&lt;/P&gt;
&lt;P&gt;&lt;A href="https://support.ptc.com/help/creo/creo_pma/r12/usascii/#page/assembly/intelligent_fastener/IFX_Fastener_Data_Files.html#" target="_blank"&gt;Fastener Data Files&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;&lt;A href="https://support.ptc.com/help/creo/creo_pma/r12/usascii/#page/assembly/intelligent_fastener/IFX_Customize_Fastener_Library.html#" target="_blank"&gt;About Customizing the Fastener Library&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;&lt;A href="https://support.ptc.com/help/creo/creo_pma/r12/usascii/#page/assembly/intelligent_fastener/To_Modify_Fasteners.html#" target="_blank"&gt;To Modify Fasteners&lt;/A&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Fri, 21 Nov 2025 07:57:24 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044309#M14611</guid>
      <dc:creator>OliverGräbner</dc:creator>
      <dc:date>2025-11-21T07:57:24Z</dc:date>
    </item>
    <item>
      <title>Re: Intelligent fastner and personal order code</title>
      <link>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044326#M14613</link>
      <description>&lt;P data-unlink="true"&gt;So i can add a parameter in the &lt;A href="https://support.ptc.com/help/creo/creo_pma/r12/usascii/#page/assembly/intelligent_fastener/IFX_Fastener_Data_Files.html#" target="_blank" rel="noopener nofollow"&gt;Fastener Data Files&lt;/A&gt;&amp;nbsp;of an existing fastner from "Allowable Model Parameters"&amp;nbsp;and use it in the bom ?&lt;BR /&gt;For example, i can add&amp;nbsp;PTC_WM_PART_NAME in the fastner data of a "din 912" and write my&amp;nbsp;personal codification?&lt;/P&gt;</description>
      <pubDate>Fri, 21 Nov 2025 09:40:17 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044326#M14613</guid>
      <dc:creator>AC_9932786</dc:creator>
      <dc:date>2025-11-21T09:40:17Z</dc:date>
    </item>
    <item>
      <title>Re: Intelligent fastner and personal order code</title>
      <link>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044328#M14614</link>
      <description>&lt;P&gt;Yes, this is possible. But you should not use the PTC_* parameter.&lt;/P&gt;
&lt;P&gt;They are reserved for PTC and they are normally locked.&lt;/P&gt;</description>
      <pubDate>Fri, 21 Nov 2025 09:44:01 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044328#M14614</guid>
      <dc:creator>OliverGräbner</dc:creator>
      <dc:date>2025-11-21T09:44:01Z</dc:date>
    </item>
    <item>
      <title>Re: Intelligent fastner and personal order code</title>
      <link>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044335#M14616</link>
      <description>&lt;P&gt;Thank you, have a nice day.&lt;/P&gt;</description>
      <pubDate>Fri, 21 Nov 2025 10:17:08 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044335#M14616</guid>
      <dc:creator>AC_9932786</dc:creator>
      <dc:date>2025-11-21T10:17:08Z</dc:date>
    </item>
    <item>
      <title>Re: Intelligent fastner and personal order code</title>
      <link>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044624#M14624</link>
      <description>&lt;P&gt;I'm trying as shown in the picture by using the "PDMREV" parameter to add my code, i&amp;nbsp;restart the program but i noticed as shown in the second picture that the new parameter does not appear in the parameter of the component.&lt;BR /&gt;&lt;BR /&gt;&lt;/P&gt;</description>
      <pubDate>Mon, 24 Nov 2025 11:09:36 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044624#M14624</guid>
      <dc:creator>AC_9932786</dc:creator>
      <dc:date>2025-11-24T11:09:36Z</dc:date>
    </item>
    <item>
      <title>Re: Intelligent fastner and personal order code</title>
      <link>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044634#M14625</link>
      <description>&lt;P&gt;I think using PDMREV is not possible.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;All PRO*, PDM*, PTC*, MC*, ... parameters are reserved for use from Creo.&lt;/P&gt;
&lt;P&gt;It is not possible to create a parameter with the name&amp;nbsp;&lt;SPAN&gt;PDMREV.&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;You can modify the values for this parameters:&lt;/P&gt;
&lt;UL&gt;
&lt;LI&gt;BUW_NAME&lt;/LI&gt;
&lt;LI&gt;BUW_TYPE&lt;/LI&gt;
&lt;LI&gt;BUW_SIZE&lt;/LI&gt;
&lt;LI&gt;NAMING&lt;/LI&gt;
&lt;LI&gt;DESIGNATION&lt;/LI&gt;
&lt;/UL&gt;
&lt;P&gt;If you require other parameter names, you have to purcase the full version.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 24 Nov 2025 12:06:25 GMT</pubDate>
      <guid>https://www.ptcusercommunity.com/t5/Customization/Intelligent-fastner-and-personal-order-code/m-p/1044634#M14625</guid>
      <dc:creator>OliverGräbner</dc:creator>
      <dc:date>2025-11-24T12:06:25Z</dc:date>
    </item>
  </channel>
</rss>
