When I choose a chamfer or countersink callout from model annotations, it currently defaults to ANGLE X DISTANCE. How would I reverse that to say DISTANCE X ANGLE?
Solved! Go to Solution.
Go to the model properties > detail options and set the option below as required. ![]()

Go to the model properties > detail options and set the option below as required. ![]()